Rosemount 8800 Reducer Vortex Flowmeter

Rosemount™ 8800 Series

The Rosemount 8800 Reducer Vortex Flowmeter utilizes the proven electronics, sensors and meter body of the Rosemount 8800 Series and takes advantage of the integrated reducer to accurately measure small flow rates. The design eliminates the need for on-site assembly and welding of split reducers and piping, thereby significantly reducing installation costs and project risks. Additionally, the Rosemount 8800 Reducer matches face-to-face dimensions with the traditional Rosemount 8800 Series, thereby increasing versatility.
Product details
Flowmeter accuracy
Get ±0.70% mass flow rate accuracy in water when using the 8800 MultiVariable flow meter (MTA/MCA option)
Get ±2% mass flow rate accuracy in water when using the 8800 MultiVariable flow meter (MTA/MCA option)
Get ±1.3% flow rate accuracy in steam from 30 psia to 2,000 psia when using the 8800 MultiVariable flow meter (MPA option)
Accuracy of ±1.2% flow rate at 150 psia in steam using 8800 MultiVariable flowmeter (MCA option)
Accuracy of ±1.3% of flow rate at 300 psia in steam with 8800 MultiVariable flow meter (MCA option)
When using the 8800 MultiVariable flow meter (MCA option), obtain flow rate accuracy of ± 1.6% at 800 psia in steam
Accuracy of ±2.5% flow rate at 2,000 psia in steam with 8800 MultiVariable flowmeter (MCA option)
Liquid volumetric flow rate ± 0.65% accuracy (uncompensated)
Gas and steam volumetric flow rates ± 1% accuracy (uncompensated)
Turndown
38:1
output
4-20mA based on HART® or 7
4-20mA based on HART® 5 or 7 and adjustable pulse output
FOUNDATION fieldbus ITK6 with 2 analog input modules, 1 backup link active scheduler function block, 1 integrator function block and 1 PID function block
Modbus RS-485 with device status and 4 variables
Wetted material
Stainless steel; 316/316L and CF3M
Nickel Alloys – C-22 and CW2M
High Temperature Carbon Steel – A105 and WCB
Low Temperature Carbon Steels – LF2 and LCC
Duplex UNS S32760 and 6A
For other wetted materials, please consult the manufacturer.
Flange options
ANSI Class 150 to 1500
FROM PN 10 to PN 160
JIS 10K to 40K
The flange surface has multiple orientations
For other flange specifications, please consult the manufacturer
operating temperature
-330°F to 800°F (-200°C to 427°C)
Pipe diameter
1" to 14" (25 to 350mm)