Rosemount™ 5900C Radar Level Gauge
Rosemount™ 5900 Series
- Accuracy
- ±1mm (0.04in.)、±2mm (0.08in.)
- stability
- Typically < ± 0.5mm (0.020in.) at -40 to +70°C (-40 to +158°F).
- update rate
- The measurement is re-measured every 0.3 seconds.
- Communication protocol
- Foundation™ Fieldbus connects to the Rosemount 2410 via a self-configuring Tankbus or Foundation™ Fieldbus master system.
The Rosemount 5900 Level Gauge works with the 2410 Tank Hub to communicate wirelessly and emulate other manufacturers' gauges.
- Safety
- • SIL 2 certified.
• Overfill protection is TÜV tested and WHG certified.
- Simulation function
- Can be integrated with traditional tank gauging systems.
- power supply
- • FISCO: 9.0 - 17.5VDC, no distinction between positive and negative poles (eg 2410 Tank Hub).
• Entity: 9.0 - 30.0VDC, no distinction between positive and negative poles.
- ambient temperature
- -40 to +70°C (-40 to +158°F). Minimum startup temperature is -50°C (-58°F).
- Antenna type
- Parabolic antennas, still tube array antennas, cone antennas, LPG/LNG antennas, 1in. and 2in. antennas. Stilltube antenna.