Rosemount™ 5900 Series Radar Level Gauge
Rosemount™ 5900 Series
- Accuracy
- ± 0.5 mm(± 0.020 in.)。
- stability
- Typically < ± 0.5 mm (0.020 in.) at –40 to +70°C (–40 to +158°F).
- update rate
- The measurement is re-measured every 0.3 seconds.
- Communication protocol
- Foundation™ Fieldbus connects to the Rosemount 2410 via a self-configuring Tankbus or Foundation™ Fieldbus master system.
The Rosemount 5900 Level Gauge works with the 2410 Tank Hub to communicate wirelessly and emulate other manufacturers' gauges.
- custody transfer certification
- OIML R85:2008 and national certifications such as PTB, NMi, etc.
- Safety
- • SIL 2 and SIL 3 certified.
• Overfill protection is TÜV tested and WHG certified.
- Metering seal
- yes.
- Simulation function
- Can be integrated with traditional tank gauging systems.
Supports simulation of communication protocols from other manufacturers: such as Enraf, L&J Tankway, Varec Mark/Space, Whessoe, GPE, Sakura and Tokyo Keiso.
- power supply
- • FISCO: 9.0 - 17.5 VDC does not differentiate between positive and negative poles (e.g. 2410 Tank Hub).
• Entity: 9.0 - 30.0 VDC does not distinguish between positive and negative poles.
- ambient temperature
- -40 to +70 °C (-40 to +158 °F). Minimum starting temperature is -50 °C (-58 °F).
- Antenna type
- Parabolic antenna, waveguide array antenna, horn antenna, LPG/LNG antenna